UG-5-AFR-24V-ST2  - Calectro Magyarország  Sales

BRAND Calectro
Product UG-5-AFR-24V-ST2
Description air duct smoke switch 24 V AC/DC
Internal code IMP4622222
Custom code 85311030
Technical specification 24 V AC/DC The Uniguard smoke detector is designed to detect smoke in ventilation ducts and combines a smoke detector with an adapter system, the pipe and housing being specially designed for optimal air flow through the smoke detector.The UG-5 can be installed on each side of the duct in four different positions: 0°, 90°, 180° and 270°. Patented. Comes complete with air duct removal pipe, 0.6 m length Power supply: 24 V AC/DC -15%, +10% Smoke detector type: UG-5-AFR-24V optical Max current consumption: 220 mA Operating temperature: -10°C to +55°C Max Humidity: 99% RH Air speed range: 1 to 20 m/s Approvals: VdS G213014, CE, pren-54-27 Smoke alarm release via remote reset Relay output: Potential free Smoke alarm relay: Two changeover contacts 250 V, 8A Service alarm: One changeover contact 250 V, 5 A System fault alarm: One changeover contact 250 V, 5 A Air speed alarm: One switching contact 250 V, 5 A LED on smoke detector: Green: Service alarm (contamination) red - smoke alarm LED on printed circuit board: Green: normal operation yellow - system error yellow - air speed alarm Adapter housing: ABS Protection class: IP54

Please send us your request per e-mail, so we can send you our offer with competitive prices and delivery time for Calectro - UG-5-AFR-24V-ST2 air duct smoke switch 24 V AC/DC number or any other model you need. We can offer competitive price, and delivery time with wide products distribution network in Magyarország Industrial products Market.

WE SELL ONLY NEW AND ORIGINAL PRODUCTS!

More products of Calectro

UG-5-AFR-230V-Z-ST2

Calectro Luftkanalrauchschalter

ST-P-DA

Optical smoke detector

UG-5-AFR-230V

Duct Smoke Detector for Air Ventilation

UG-5-AFR-230V-Z

air duct smoke switch

UG-5-AFR-230V

Air duct smoke detector

STB-4SE-24VR

Socket for smoke detector ST-P-DA/EVC-PY-DA

UG-2-A20

Fire alarm switch

UG-5-AFR-24V-ST2

air duct smoke switch 24 V AC/DC

ST2

Venturi-Rohr Länge 600 mm für UG-5

UG-MB-75

console

UG-Cover-75

protective housing

ABAV-S3-230V

Steuergerät

CPS-A

Differential pressure transmitter -50 - +3500 Pa

UG-5-AFR-24V.

Complete unit including the alarm inside it

CPS-D-A

differential pressure transmitter

VR-0.6m

venturi tube

UG-3-A4-0

Air duct smoke detector 24 V AC/DC

CLA-24/230V

Leakage alarm for electrically conductive liquids

UG-3-A5-0

air duct smoke switch

Contact us for request