Technical specification Model Code DVH-V-H55S-LL2S0-H Process data: Medium - Name Oil Display range 1,110 - 4,500 l/min Pipeline inner diameter 159.3 mm Process temperature 90 °C Process pressure p e 8 bar accuracies Volume flow accuracy ± 0.7% of the measured value Repeatability volume ± 0.1% of the measured value Valve data: Evaluate electronics volume Volume measurement for liquid, gas, steam DN150 PN40 Form B1 EN1092-1 process connection Material flow sensor stainless steel 1.4404/1.4571 Installation length 300 mm Compact sensor configuration incl. LCD display Compact transmitter, IP66 2-line LCD display, 16 digits each, fully configurable Power supply 12-36 VDC; 2-wire passive current output 2-wire version output signal 1x 4-20mA HART, 1x Impulse Process temperature Standard temperature -40 to +260°C (-40 to +500°F) Explosion protection ATEX ATEX IIG Ex d IIB + H2 T6/IEC Ex xxxx