89216,TOPAS PMW - OBSOLETE   - Integra Metering AG (formerly Aquametro) Magyarország  Sales

BRAND Integra Metering AG (formerly Aquametro)
Product 89216,TOPAS PMW - OBSOLETE
Description Nominal flow: Qn = 10; Nominal diameter: DN 40; Reporting: 1 liter of 1impuls water meter
Internal code IMP175105
Weight 1

Please Contact Us to Order to offer competitive prices and delivery time for Integra Metering AG (formerly Aquametro) - 89216,TOPAS PMW - OBSOLETE Nominal flow: Qn = 10; Nominal diameter: DN 40; Reporting: 1 liter of 1impuls water meter number, also you may ask some other model number is well. We can offer competitive price, and delivery time with wide products distribution network in Magyarország Industrial products Market. 

WE SELL ONLY NEW AND ORIGINAL PRODUCTS!

Our company is not an authorized distributor. All rights are reserved by the manufacturers and their official partners.

More products of Integra Metering AG (formerly Aquametro)

93533

[AMBUS IS M-Bus pulse collector 1 pulse input 2 conductors M-bus interface 2 conductors with energy supply from AMBUS ZS or Net]

94249

PMG 32-RH1 6.0_260_1 G1 / 4 multi-jet vane hot water meter in glanded Thread connection: G 1 1/2 " Nominal size: DN 32 Mounting length: 260 mm Mounting position: horizontal Temperature: max. 130 ° C Nominal pressure: PN 16 Minimum flow qi: 0,075 m³ / h Continuous flow qp: 6 m³ / h Maximum flow qs: 12 m³ / h Kvs-value: 12.7 m³ / h Pressure loss at qp: 0,22 bar Pulse value: 1 liter / pulse Environmental class C according to EN 1434 no inlet: 0 x DN 32 no outlet flow: 0 x DN 32 Approval MI-004

94252 PMGF 32-RH1 5.0_150_1 1/4"

Size: DN 32 with thread 1 1/2 "(for screw 1 1/4") Nominal pressure: PN 16 bar length: 150 mm Mounting position: vertical falling temperature max .: 130 ° C Maximum flow qs: 6.3 m3 / h Nominal flow qp: 5 m3 / h minimum flow qi: 0.1 m3 / h pulse value: 1 l Smallest readable amount: 0.1 l registrable: 99,999 m3 measuring principle: multi-jet impeller, dry running With CE marking

94255

PMGS 32-RH1 5.0_150_1 G1 / 4 multi-jet vane hot water meter in glanded Thread connection: G 1 1/2 " Nominal size: DN 32 Mounting length: 150 mm Mounting position: vertical ascending Riser counter Temperature: max. 130 ° C Nominal pressure: PN 16 Minimum flow qi: 0.1 m³ / h Continuous flow qp: 5 m³ / h Maximum flow qs: 6,3 m³ / h Kvs-value: 13.6 m³ / h Pressure loss at qp: 0,14 bar Pulse value: 1 liter / pulse Environmental class C according to EN 1434 no inlet: 0 x DN 32 no outlet flow: 0 x DN 32 Approval MI-004

94525 50 50_200

MeiStream RUBIN cold water meters Nominal size: DN 50 Flange connection: EN 1092-1 Nominal pressure: PN 16 bar Overall length: 200 mm Mounting position: horizontal / vertical Protection: IP 68 Temperature max .: 50 ° C Overload flow Q4: 90 m3 / h Permanent flow rate Q3: 50 m3 / h Transition flow rate Q2: 0.4 m3 / h Minimum flow rate Q1: 0.15 m3 / h Smallest readable amount: 0.5 l Registration capacity: 1 million m3 Measuring principle: Woltman turbine Measuring range delivery designation: R 100

94604

PMW-basic 32 10._260_1 G1 / 4; Multi-jet vane hot water meter in glanded Thread connection: G 1 1/2 " Nominal size: DN 32 Mounting length: 260 mm Mounting position: horizontal Temperature max. 90 ° C. Nominal pressure: PN 16 Minimum flow Q1: 0.1 m³ / h Permanent flow Q3: 10 m³ / h Maximum flow Q4: 12.5 m³ / h Kvs-value: 12.7 m³ / h Pressure loss in Q3: 600 mbar Measuring range: R 100 Inlet section: 0 x DN 32 Outlet flow: 0 x DN 32 Degree of protection: IP 66 Approval MI-001

94606

PMWF-basic 32 10._150_1 G1 / 4 multi-jet vane hot water meter in glanded Thread connection: G 1 1/2 " Nominal size: DN 32 Mounting length: 150 mm Mounting position: vertical falling Pipe meter Temperature max. 90 ° C. Nominal pressure: PN 16 Minimum flow Q1: 0.1 m³ / h Permanent flow Q3: 10 m³ / h Maximum flow Q4: 12.5 m³ / h Kvs-value: 10.3 m³ / h Pressure loss in Q3: 900 mbar Measuring range: R 100 Inlet section: 0 x DN 32 Outlet flow: 0 x DN 32 Degree of protection: IP 66 Approval MI-001

94607

PMW-basic 16._300_1 40 1/2 ''; Multi-jet vane hot water meter in glanded Thread connection: G 1 " Nominal size: DN 40 Mounting length: 300 mm Mounting position: horizontal Temperature max. 90 ° C. Nominal pressure: PN 16 Minimum flow Q1: 0.16 m³ / h Permanent flow Q3: 16 m³ / h Maximum flow Q4: 20 m³ / h Kvs-value: 25.6 m³ / h Pressure loss in Q3: 400 mbar Measuring range: R 100 Inlet section: 0 x DN 40 Outlet flow: 0 x DN 40 Degree of protection: IP 66 Approval MI-001

94608

PMWS-basic 16._200_1 40 1/2 ''; Multi-jet vane hot water meter in glanded Connection thread: G 2 " Nominal size: DN 40 Mounting length: 200 mm Mounting position: vertical ascending Riser counter Temperature max. 90 ° C. Nominal pressure: PN 16 Minimum flow Q1: 0,16m³ / h Permanent flow Q3: 16 m³ / h Maximum flow Q4: 20 m³ / h Kvs-value: 20.8 m³ / h Pressure loss in Q3: 600 mbar Measuring range: R 100 Inlet section: 0 x DN 40 Outlet flow: 0 x DN 40 Degree of protection: IP 66 Approval MI-001

94609

PMWF-basic 16._200_1 40 1/2 ''; Multi-jet vane hot water meter in glanded Connection thread: G 2 " Nominal size: DN 40 Mounting length: 200 mm Mounting position: vertical falling Pipe meter Temperature max. 90 ° C. Nominal pressure: PN 16 Minimum flow Q1: 0,16m³ / h Permanent flow Q3: 16 m³ / h Maximum flow Q4: 20 m³ / h Kvs-value: 22.2 m³ / h Pressure loss in Q3: 600 mbar Measuring range: R 100 Inlet section: 0 x DN 40 Outlet flow: 0 x DN 40 Degree of protection: IP 66 Approval MI-001

96166.

CE test water meter R49 DN15-32

96167

CE test water meter R49 DN40-50

ART.NO. 80113/2008 AQUAPULS 1L

System module aquapuls® For retrofitting aquabasic® cold water meters. Pulse value 1 l / pulse with return compensation. Switching capacity 220 mA / 48 VDC. Degree of protection IP 68 with 1.5 m cable, fixed. With battery power

ART.NO. 83527 RV1/RD 20

DOMINO ® ARD structure group - Reguliergetriebe - Roller 6 digits, with RV Reed pulser, 48 VAC / DC, 50 mA, 2 W Specifications: Recording capacity Roller: 107 l Smallest readable Quantity: 0.1 l Pulse Value: 1 l

ART.NO. 92048 VZO 20 RC 130/16-RV1

CONTOIL® oil meter VZO 20 RC 130/16-RV 1 Ring piston meter for mineral oil, with rotatable roller counter

P/N 92280, VZF 50 FL 180/25

P/N 92280 Aquametro Oil Meter

P/N 94101

VZO 25 FL 180 / EXP 10-20K

P/N: 89763 VZO 4 -RE 0,00125

[CONTOIL ® fuel oil meters Reed pulser Pulse value 1.25 ml Nominal width: 4 mm With internal thread copper pipe: 1/8 " Nominal pressure: PN 25 Maximum permissible temperature: 50 ° C Mounting position: horizontal / vertical Largest flow Qmax. 80 l / h In continuous operation: 50 l / h Error of measurement: 1-80 l / h + / - 1% of the measurement error Recording capacity Roller 100 000 liters With built-on Reed pulser RE max:. 48V AC / DC, max. 50 mA, max. 3 VA Pulse value: 0.00125 l]

TMC19321

vzo-4 fuel counter

VCS04

MOTOR AC230V 50/60HZ DN25 WITH CAPACITOR AND GEAR FOR ACTUATOR TYPE: 2KN:

VZ020

fuel counter gear

VZ025

fuel counter gear

VZO 15 RC 130/16-RV0,1

(92042, CONTOIL® oil meter Reed pulser Pulse value 0.1 l, nominal width: 15 mm DN With 3/4 "thread for fittings: 1/2" Overall length: 165 mm Nominal pressure: PN 16 bar Max. Permissible temperature: 130 ° C Mounting position: horizontal / vertical Largest flow Qmax .: 600 l / h In continuous operation Qn .: 400 l / h Minimum flow rate Qmin .: 10 l / h Bias: 10-600 l / h ± 1% of reading Repeatability equal / better than 0.2% Total amount on roller 1 000 000 l Smallest readable Quantity: 0.01 l Pulser Reed, max.48 V AC / DC, 50 mA, 2 W Pulse value: 0.1 l Measuring principle: piston ring)

VZO 20 FL 130/25-IN0,01 91903

Oil meter with roller Measuring accuracy ± 1% Medium temperature to 130 ° C Roller counter with pulse generator, optionally Reed (RV) or Namur (IN) VZO 15 ... 50 with Flange EN 1092-1, PN 25

VZO-15

fuel meter

94606 PMWF-basic 32 10._150_1 1/4"

TOPAS hot water meter, Nominal Size: DN 32,With thread 1 1/2 "(for screw 1 1/4"),Nominal pressure: PN 16 bar,Overall length: 150 mm,Mounting position: vertical falling,Temperature max .: 90 ° C,Overload flow Q4: 12.5 m3 / h,Permanent flow rate Q3: 10 m3 / h,Transition flow Q2: 12:16 m3 / h,Minimum flow rate Q1: 0.1 m3 / h,Measuring range: R 100,Smallest readable amount: 0.1 l,Registrable: 100000 m3,Measuring principle: multi-jet turbine, dry running

96158

CE test hydr. Encoder EN1434 DN15-32

Contact us for request