RC200  - Badger Meter Magyarország  Sales

BRAND Badger Meter
Product RC200
Description Process Control Valve
Internal code IMP16874
Weight 1
Technical specification Nominal width: 1/4" Valve housing: Passage, cast, material 316SST Connection: 1/4" NPT internal thread Valve top: Standard, Material 316SST Spindle sealing: roof collars, material PTFE/PFA Interior set: size “F” linear, Kvs 0.27, cone and seat from 316 SST Actuator: Pneumatic, spring closes, type 754, ATO, signal 0.2-1.0 bar Positioner: No Mounting grease: Silicone-containing “Dow 111"

Please Contact Us to Order to offer competitive prices and delivery time for Badger Meter - RC200 Process Control Valve number, also you may ask some other model number is well. We can offer competitive price, and delivery time with wide products distribution network in Magyarország Industrial products Market. 

WE SELL ONLY NEW AND ORIGINAL PRODUCTS!

Our company is not an authorized distributor. All rights are reserved by the manufacturers and their official partners.

More products of Badger Meter

CABLE

SN: 0506-067 0-75 meters for DN 50 Electromagnetic Flowmeter 3 x (2 x 0.25 mm²) + Ground of 160 Ω / km

KT 201403193

MID M 1000 flange ISO DN 100 PN 16 Hard rubber Hastelloy C 230VAC

KT 20140417

MID M 1000 with ISO flange DN 150 Hard rubber Hastelloy C 230VAC

LIQUID FLOW METER RCDL M70, WITH PULSE GENERATOR PFT-1E.

Body: Bronze Measuring chamber: Vectra O-rings: Viton Measuring range: 18 - 265 l / min Accuracy: + / - 1.5% of the value p-max: 16 bar t-max: 120 ° C Connection: R 1 1/4 "male Length: 273 mm Mounting position: horizontal, vertical Pulse Output: Transistor NPN open Scale Factor: 0.00001 to 0.9999 Supply: 12-24 VDC

LM OG-CND 

for petrol, oil, digital and electronic counters, rotary platforms ½, flow. 0-28 I / min

LM OG-PND P114

Product preset Max 120°F/50°C Min 20°F/-5°C 868 mhz

B102101

Einbauzähler mit Impulsgeber für Schmieröl

M2000 AM DN50

ELECTROMAGNETIC FLOW METER

MAGNETOFLOW TYP II DN 65 / PN 16

Magnetic flowmeter with transmitter M1500 for full pipes.

MID 2-100/16-F/ST-WG-ML/HC-ST M15A SK1

Type II DN 100 / PN 16 with amplifier M1500 for full pipes

MID M 1000 MIT FLANSCH DN 32 HARTGUMMI HASTELLOY C 24VDC

Magnetic flowmeter Magneto Flow Type II DN 32 / PN 16 with transmitter for M2000 full pipes.

MN7

schetchik jidkosti

MN80AAP-1

MN SERİES,70-733 LPM 1200 KPA 3”/80MM BSP

MODEL RCDL M25

BADGER METER RCDL DISC METERS POSITIVE DISPLACEMENT – NUTATING DISC

RCDL LCR

Register with pulse output, Electronic counter LCR type with an LCD display and, pulse output above for OG-Baureihe.Anzeige 1: resettable totalizer or flow indication programmable, Format xxxx.x. Display 2: Non-resettable totalizer, 14 digits. Memory display: EEPROM, data retention in battery replacement Units: liters, gallons, pints, quarts Temperature: 0-70 ° C Pulse acquisition: Reed, max.50Hz Input pulse: from 1.00 to 17000.00 (numerator) Correction factor: 0.5000 to 2.0000 Power supply: 3 VDC Lithium CR 1/2 AA Protection: IP 64 For counter Size: M25-M35-M40-M70-M120-M170 Pulse output: NPN, MOSFET 40V / 2A Pulse factor: 0.01-99.99 Pulse length: 10ms (2ms, 20ms, 40ms) Ext.Stromversorg. : 8-24VDC Pulse output PPL: 0,01-0,1-1-10-100 Dosing control: 0.01 to 999.99 Preliminary circuit: from 0.00 to 99.99 Switching output: NPN, MOSFET 40V / 2A

RCDL LCR REGISTER MIT IMPULSAUSGANG U. STROMAUSGANG 4-20MA

Electronic counter LCR type with an LCD display, Display 1: resettable totalizer or Flow display programmable, Format xxx.xx. Display 2: Non-resettable totalizer 14 digits. Memory display: EEPROM, data retention in battery replacement Units: liters, gallons, pints, quarts Temperature: 0-70 ° C Pulse acquisition: Reed, max.50Hz Input pulse: from 1.00 to 17000.00 (numerator) Correction factor: 0.5000 to 2.0000 Power supply: 3 VDC Lithium CR 1/2 AA

RCDL LCR REGISTER OHNE IMPULSAUSGANG

Electronic counter LCR type with an LCD display, for the OG series Display 1: resettable totalizer or Flow display programmable, format xxxx.x Display 2: Non-resettable totalizer 14 digits Memory display: EEPROM, data retention in battery replacement Units: liters, gallons, pints, quarts Temperature: 0-70 ° C Pulse acquisition: Reed, max.50Hz Input pulse: from 1.00 to 17000.00 (numerator) Correction factor: 0.5000 to 2.0000 Power supply: 3 VDC Lithium CR 1/2 AA Protection: IP 64

RCDL M25

3/4 "or 1" PPO Viton without pulse, fluid meter RCDL M25 without construction. Material and technical data: Housing: Nylon Measuring chamber: Noryl (PPO) O-rings: Viton Measuring range: 1-100 l / min Accuracy: +/- 1.5% of the value p-max: 10 bar t-max: 50 ° C Connection: R 3/4 "or R 1" Installation length: 190 mm Installation position: horizontal, standing

RCDL M25 1"

Vectra Viton pulse PFT-2 reed contact Liquid meter RCDL M25 without construction. Materials and technical data: Housing: Bronze Measuring chamber: Vectra O-rings: Viton Measuring range: 3-100 l / min Accuracy: +/- 1.5% of the value p-max: 10 bar t-max: ° C Connection: R 1 "outside Installation length: 190 mm Installation position: horizontal, standing 604011 Pulse PFT-2 reed contact about 52 PPL

RCDL M25 3/4" ODER 1" PPO VITON OHNE IMPULSGEBER

(Liquid meter RCDL M25 without Construction. Material and technical data: Housing: Nylon Measuring chamber: Noryl (PPO) O-rings: Viton Measuring range: 1-100 l / min Accuracy: +/- 1.5% of the value p-max: 10 bar t-max: 50 ° C Connection: R 3/4 "or R 1" Installation length: 190 mm Installation position: horizontal, vertical)

RCDL M25, WITH PULSE- TRANSMITTER PFT-1E - 52,4 PULSE/LITER SETUP

Housing : Bronze Chamber : Noryl (PPO) O-Rings : Buna Flowrange : 1-100 l/min Accuracy : +/- 1,5 % of value p-max : 10 bar t-max : 50 °C Connection : Threads 1" male Laylength : 190mm Pulsoutput : Open Collector NPN Scale Factor : 0.00001 to 0.9999 Supply : 12-24 VDC Pulsoutput : S/N : Part-Nr. 141158

KT M2000 50

MID M 2000 mit Flansch DN 50 1.4571

106126

Oval wheel counter

Other Category Brands